Products
Cable head GOST 14213

Cable heads CH-1(3,7)-36(42,60) are designed for mechanical and electrical connection of single-core, three-core, seven-core load-bearing armored geophysical cables with logging equipment during geophysical works in wells.

“PGFS” LLC has updated its classic design, the distinctive feature of the cable lugs manufactured by “PGFS” LLC is the threaded cable gland with sealing rings, an optimal angle of approach allowing to pass through the well shoulders without any complications is selected, the socket is covered with a special material to improve the isolation characteristics. All products are carefully processed, burrs, roughnesses are removed, and quality protective chrome coating makes cable heads of our production beyond competition. An additional advantage is the delivery of assembled cable heads, the user only needs to terminate the cable armor and insulate the cores.

Cable heads can be made resistant to aggressive environment and high temperature.

By choosing “PGFS” LLC, you are choosing quality!

Technical characteristics

Name of tested parameters

and characteristics

Nominal value Permit
Ambient working environment temperature, °С -50 till +120(200) According to the customer’s specification
Upper value of hydrostatic pressure, MPa 100 Not more
Thread type
 CH-1(3)-36 М33х1,5 According to the customer’s specification
CH-1(3)-42 М33х1,5 According to the customer’s specification
CH-1(3,7)-60 М55х2 According to the customer’s specification
Number of cable cores 1÷7 According to the customer’s specification
Cable diameter, mm 6÷11
6÷15
According to the customer’s specification
Insulation resistance of electrical circuits between each other and against the enclosure, Mohm 50 Not less
Overall dimensions, diameter, length, mm
CH-1(3)-36 36х400 Not more
CH-1(3)-42 42х400 Not more
CH-1(3,7)-60 60х400 Not more
Weight, kg:
CH-1(3)-36 1,6 Not more
CH-1(3)-42 2,2 Not more
CH-1(3,7)-60 3,7 Not more
Working environment Water, oil, mud According to the customer’s specification
(К1,К2,К2.1,К3)
Maximum allowable tensile load on the connecting thread of the cable head, t 16 Not more
Material 40Х According to the customer’s specification
Covering Chemical
parkerising
According to the customer’s specification
Chroming According to the customer’s specification